> Both 120 degrees out of phase. So if you remember elementary school math the abs() of phase A at its peak of +120 and phase B at it's valley of -120 = 240. I
by ghouse 6y ago
> Both 120 degrees out of phase. So if you remember elementary school math the abs() of phase A at its peak of +120 and phase B at it's valley of -120 = 240.
I think you mean 180 degrees out of phase.
- labcomputer 6y agoIt's not clear what he meant (because this part doesn't really have anything to do with 3-phase), but: Most houses in the US have 240V service for large loads like A/C, ovens, stoves, dryers, EV chargers, etc. The way you get 240V (in the US) is that you take a single phase, and apply it to a transformer. The transformer's secondary has a grounded center tap, so you get +/- 120V, 180 degrees out of phase (this is called "split phase").