3 ms·
I once worked on a construction defect lawsuit involving a radiant system with pipes embedded in concrete, and repairs were a costly nightmare whenever anything
by staticautomatic 6y ago
I once worked on a construction defect lawsuit involving a radiant system with pipes embedded in concrete, and repairs were a costly nightmare whenever anything went wrong. Is putting them in concrete uncommon?
- galfarragem 6y agoEmbedding them in mortar (cement + sand + water)[0] is standard if not mandatory. I helped installing them in several houses and never had any problem. Relevant best practices to prevent problems by thermal dilatations in radiant floors: using the right amount of mortar aditives, using an approved isolant base for the pipes and using a foam stripe between walls and radiant floor. [0] Concrete = cement + sand + water + small rocks and often uses a grid made of structural steel.