You know that's a 12,000 watt connector right? I was surprised how many people do not know. 14-50 => 12000 watts (provided at some rv parks) tt-30 => 3600 wa
by m463 6y ago
You know that's a 12,000 watt connector right?
I was surprised how many people do not know.
14-50 => 12000 watts (provided at some rv parks)
tt-30 => 3600 watts (rv 30-amp provided at most parks)
5-15 => 1800 watts.
As to the original article - I think it might be ok to plug that into a 5-20R:
https://upload.wikimedia.org/wikipedia/commons/4/42/Electrical_outlet_with_label.jpg https://upload.wikimedia.org/wikipedia/commons/4/42/Electric...
but yeah - it should really have a right-angle connector.
and it should have someone's name on it or be locked in someone's desk drawer.
- stickfigure 6y agoYou say this like it's somehow going to generate 12000 watts, or that somehow having an overbuilt cable is dangerous? Yes, the connector is way overbuilt for running 15amp 120v loads, but that's a good thing. You don't want the connector to be the weakest link. I'm not sure why you think wattage numbers are more relevant than amperage numbers? Amps are what heat the cable and blow breakers. Unless it's fused, absolutely nothing about a cable or connector stops you from drawing excessive amperage through it. You use splitters probably every day, and every one of those receptacles is capable of drawing full amperage. If you draw too much you pop the breaker in the panel. The breaker must always be rated lower than the wiring attached to it. Everyone with an old house who has tried to run the microwave, toaster, and fridge at the same time has experienced this. 14-50 plugs are more interesting than all this because they're two hots, a neutral, and a ground. If you adapt it to 120v shore power (with a 5-15 plug) you are using split phase power, so one of the hots will be dead. In theory you could draw 50 amps of 120v through that cable, but the box you're plugging into will pop the circuit long before then. Also, this is why your rooftop A/C doesn't work when plugged into 120v shore power - rooftop air conditioners are usually 240v appliances.
- m463 6y agoI didn't use amps because that is exactly what confuses people. They use 30 amp pigtails for a 50 amp connector and figure it's just a little more. Would it work better if I said 50 amp @ 240 is really 100 amp @ 120? I have not extensively tested a 15-amp pigtail but as far as I know the circuit is identical. I have a 15->30 plus a 30->50. (btw rooftop AC is 120v and all circuits/both legs work in my rv plugged into a pigtail)
- kortilla 6y agoI could point to a giant copper rod being used to carry 15 amps and exclaim “you know that’s a 5 megawatt connector, right?” and it would be the same as what you are doing here. It doesn’t matter what the potential max capacity of something you plug in is. The breakers on the supply are the limiting factor (they should trip before anything down-line exceeds service). A toaster has a super high max capacity when you throw it in the bathtub. Doesn’t mean plugging in a toaster is dangerous.
- m463 6y agoI was trying to give a direct scale. Maybe I should have said 100 amps vs 15 amps. article to read: http://rvservices.koa.com/rvinformation/rvmaintenance/rv-electrical-101.asp http://rvservices.koa.com/rvinformation/rvmaintenance/rv-ele...