5 ms·
this picture is worth 987 words: https://circuitcellar.com/wp-content/uploads/2020/03/343-Lacoste-Figure_14.jpg https://circuitcellar.com/wp-content/uploads/20
by m463 6y ago
this picture is worth 987 words:
https://circuitcellar.com/wp-content/uploads/2020/03/343-Lacoste-Figure_14.jpg https://circuitcellar.com/wp-content/uploads/2020/03/343-Lac...
although these 13 words help it get to 1000:
"An example of a quite exotic old probe, a 40-kV rated Tektronix P6015"
- lmilcin 6y agoUnfortunately, it is not going to help your scope a bit if you make a short when connecting ground...
- akiselev 6y agoMost things that put off enough voltage to require one of those probes arc through air at that distance. If it's close enough for a clusmy person to short something, it's already either blown up or the insulation is thick enough to withstand some awkward poking with a probe (or its submerged in an oil or other nonpolar solvent).
- pjc50 6y agoUsing that thing must be quite a hair-raising experience. (The "Z0" probe idea is great, though, I shall have to remember that one)
- ethhics 6y agoI’ve used the similar Fluke 80K-40 a number of times up to 20 kVrms. The arcing is always concerning, but it’s surprising how safe it feels to hold.