4 ms·
> Having individual heating and cooling units (per unit gas heaters!) is stupendously inefficient. > Contrast this with a condo in Minneapolis that I own where
by amluto 6y ago
> Having individual heating and cooling units (per unit gas heaters!) is stupendously inefficient.
> Contrast this with a condo in Minneapolis that I own wherein heat and AC are central in the building and individual units can set their temperature to whatever they like - all run with tremendously higher efficiency.
This needs some real data.
There are a few central technologies that might be used. A condensing gas-fired boiler might exceed 95% efficiency if you imagine that losses in the hydronic pipes are minimal. An evaporative cooling tower has awkward-to-define efficiency because it consumes water, but I doubt it works very well in Miami. A giant air-source central heat pump might be reasonably efficient (COP around 4?).
But little modern heat pumps with variable-speed drives (often marketed as "inverters") can be very efficient indeed. Fujitsu will sell you a unit right here in the USA with SEER 29 or better, and the general trend is that the smaller units are more efficient than the larger units. (Yes, SEER uses ridiculous units.)
Additionally, in most markets, a reasonably efficient heat pump is both less expensive to operate than even a 100% efficient boiler and has lower greenhouse gas emissions.
- Melkman 6y agoI know it's only one datapoint but recently we had four indoor airco units installed in our house for the bedrooms and livingroom. I expected a single outdoor unit. However during talks with the installer he advised us to go for two outdoor units. This was cheaper in hardware, a bit more efficient and way cheaper to install by placing one outdoor unit on the front of the house and one on the back so all rooms could be reached within a meter or so from the outdoor units.
- sgc 6y agoFor heat pumps more outdoor units is definitely more efficient, since the outdoor unit needs to be big enough to accommodate all connected indoor units at once, and will be on even if only one is in use. Two per unit is my go to trade off on that one, with an attempt to group together units that are more likely to be used at the same time (so no bedroom / living room split, try to stick with bedroom/bedroom and living room/dining room etc). BTW they have low profile indoor units that can be embedded flush with the ceiling or wall, so the bulkiness indoors is not even required anymore.
- PaulDavisThe1st 6y agothose ceiling mount units ... not sized for typical US construction techniques, so installing them in an existing ceiling can be quite complex. If you're doing new construction, it is possible to correctly frame up the ceiling so that installing them becomes trivial.
- brendawalsh 6y agoThere are two kinds available currently for ceiling. The cassette, that would fit into a drop ceiling, and there is also a mini-ducted unit, installed in the ceiling with small-run ducted ports. My favorite are the ones that look like picture frames.
- rsync 6y ago"This needs some real data." I agree and I, admittedly, have none. I will say, however, that a deeper dive into these efficiencies would also have to take into account the production, distribution and installation costs (embedded pollution, not dollars) of several hundred little devices vs. a single plant that is integrated into each unit during building construction. Even considering room by room optimization (turning off AC in living room while you sleep, etc.) it's hard to imagine this penciling out vs. operating + embedded costs ... (and I still suspect that just the operating costs are higher, but your point is well taken ...)
- saeranv 6y agoAt least one building science expert (Joseph Lstiburek) reccomends a decentralized approach for HVAC, with tightly sealed individual units: https://www.buildingscience.com/documents/digests/bsd-110-hvac-in-multifamily-buildings https://www.buildingscience.com/documents/digests/bsd-110-hv... Although I do wonder how that works with something like district heating/cooling systems, which seem to rely on centralized boilers and chillers to move thermal energy between buildings.
- jk700 6y agoA common form of central heating, like burning fossils kind that delivers hot water over insulated pipes to each building, is more efficient in pretty much every way and is cheap to add during building construction than doing it individually. But it's not the case with a "central AC", it's less efficient, more expensive to add during building construction and operating costs are no better. Just think about it, you can't just deliver cold over a pipe and rely on air convection, like with heat, you need to literally move cold air into each room and make it individually adjustable. It's a ridiculously inefficient complicated expensive system requiring extra space and with installation costs higher than that of all AC units individually installed.
- shajznnckfke 6y agoCould you have a split AC system with a big centralized compressor?
- yourapostasy 6y agoMake sure if you get a mini-split that you do the following around keeping the condensate drain mechanism going. I have yet to see a mini-split product manual/installation guide that gives detailed information on these operational issues. Many models let you run the condensate drain on your choice of right or left side. The unused side is often only supplied with a friction-fit drain plug. Over a period of many years, some of these plugs can shrink, not quite fall out, and then you get a real mess. Make sure the drain pipe is dry. Clean it with denatured alcohol, then let dry again. Buy a silicone sealant that carries a 20-year warranty. Buy a roll of "cork tape" [1]. Fill about 2.5 cm / 1 inch of the drain pipe with the silicone sealant. Stretch wrap the drain plug with the cork tape, so the tape thins out while sticking to the plug. Pinch/squeeze/roll the part of the tape that hangs out beyond the end of the plug so it is slightly smaller than the stem of the plug. Push the plug into the drain pipe, and try to push it all the way up to the head of the plug. The cork tape will fill out and adhere to the walls of the pipe. Finally, stretch wrap more cork tape (or self-fusing silicone waterproof tape if you don't like the stickiness on both sides of the cork tape) around the entire drain pipe and drain plug assembly, including wrapping the end, and seal up the assembly to the pipe. Mount a very slightly tilted metal shelf underneath the mini-split air handler (the part that mounts on your wall inside your building), and install an AC-mains-powered moisture sensor that cuts off power to the mini-split when triggered, at the lowest end of the shelf. Mini-splits usually use a zero-capacity drain pan to stay as slim as possible, and if they clog up at the condensate drain pipe, they overflow rapidly (within minutes). Learn how to take the plastic cowling off the unit before you mount it, document it by video or photographs, and stash it with your product manuals. Mini-split manuals usually don't show how to take them apart enough to get at the condensate drain, and most models I've seen have lots of plastic catches all over that are hard to see when you're standing on a ladder peering between the ceiling and the cowling. If you ever get biogrowth in it, you'll want to know how to take it apart. Or, if you don't want to take it apart to get at the drain, you can codge together a way to run your wet/dry shop vac to mount to the condensate drain and pull stuff out. I used a shop vac mini kit [2]. I also got a venturi-based device to try to develop more vacuum [3] with the CO2 tank I normally use to make fizzy water. [1] https://smile.amazon.com/DiversiTech-6-330-Cork-Insulation-Black/dp/B003OF7KH4/ https://smile.amazon.com/DiversiTech-6-330-Cork-Insulation-B... [2] https://smile.amazon.com/Wet-Dry-Accessories-VT1215-Attachments/dp/B0026T1FB6/ https://smile.amazon.com/Wet-Dry-Accessories-VT1215-Attachme... [3] https://smile.amazon.com/gp/product/B00CIRZGV6/ https://smile.amazon.com/gp/product/B00CIRZGV6/
- gomoboo 6y agoThose SEER 29 units are available but in my short time once selling AC units, most went for the lowest cost unit available. Those cheaper units are not as efficient. With split units the maximum efficiency attained is in the hands of the customer. Great for customer freedom, but not so great for the environment if the lowest of the low in AC units are available. Semi-related question: How is fresh air turnover handled in apartments with split AC units?
- m463 6y ago> > condo in Minneapolis > This needs some real data. Minnesota Heating Degree Days[1]: ~ 500 Minnesota Cooling Degree Days[2]: ~ 8,000-10,000 I suspect heat pumps might reach practical limits with cold temperatures. [1] https://upload.wikimedia.org/wikipedia/commons/d/da/United_States_Heating_Degree_Day_map%2C_1961-1990.jpg https://upload.wikimedia.org/wikipedia/commons/d/da/United_S... [2] https://upload.wikimedia.org/wikipedia/commons/6/6c/United_States_Cooling_Degree_Day_map%2C_1961-1990.jpg https://upload.wikimedia.org/wikipedia/commons/6/6c/United_S...
- asdfasgasdgasdg 6y agoYou reversed the numbers from your cite. Minnesota has much more heating degree days than cooling.
- m463 6y agough. and now it's too late to fix the post. thank you!
- amluto 6y agoI wonder if anyone has tried to commercialize a device that burns gas for combined heat and power and uses that power to directly drive a heat pump. Alternatively, ground source heat pumps work decently well even in very cold places, but the installation costs can be high.
- m463 6y ago> commercialize a device I think a lot of (utility scale) generators do all kinds of fancy things like waste heat recovery. https://upload.wikimedia.org/wikipedia/commons/thumb/9/96/IGCC_diagram.svg/1200px-IGCC_diagram.svg.png https://upload.wikimedia.org/wikipedia/commons/thumb/9/96/IG... It would be kind of cool to see the same thing trickle down to your home. Tesla kind of does this in reverse with the model y - it spends electricity parsimoniously, and uses a fancy heat pump to capture or dump heat.