4 ms·
About the sloping driveway thing. Yes, I see a number of driveways sloping towards the house where the builder installed a gutter just before the garage door. T
by WalterBright 6y ago
About the sloping driveway thing. Yes, I see a number of driveways sloping towards the house where the builder installed a gutter just before the garage door. This works most of the time, but then the leaves (or snow & slush) clog the gutter and the garage floods.
Your garage is going to flood if the driveway slopes towards it.
I've had a flood from a broken washing machine hose before. I had a lot of water damage to repair. This house has a floor drain under the washing machine, with (as usual) the floor sloping towards the drain. Ditto for under the water heater.
In the new house, I've had two gushers in the laundry room and one leaking water heater. No flood damage! Usually, a leaking water heater is an emergency. Not here, it could wait until normal business hours.
I have never, ever seen this feature in any other house, and it costs next to nothing.
- maxerickson 6y agoIs that a one story house? Here the basement floor is below the sewer drain and deeper eaves wouldn't do much of anything to keep the 1st floor siding clean.
- WalterBright 6y ago2 stories. But the wind usually doesn't blow hard enough for the rain to hit the side. So it works. The contractor wanted to put in a sump pump, but I wanted a gravity drain instead which required a trench to put it in, which was well worth it. (The power around here goes out whenever it rains hard, so much for the sump pump.)
- greedo 6y agoI replaced my electrical sump pump with one powered by water pressure. I figure that if both water AND electricity go out, I'm screwed anyway.
- itronitron 6y agoI once owned a house where the hot water heater and AC units were both in the attic (of a 2 story home.) One nice feature is that they both had pans underneath with drain lines to an AC condensate overflow line outside the house.
- bitbckt 6y ago> I have never, ever seen this feature in any other house, and it costs next to nothing. My house, built in 1956, features these drains.
- glxxyz 6y agoI owned a house in Edmonton where ice would form under one side of one garage door in the minus-a-lot-in-either-scale 9-month-long winters. I used to break up the ice damn daily with a mattock, fun times.
- CliffStoll 6y agoEast Bay homeowner in complete agreement! Even with no worries about freezing pipes, I made sure there's a washing machine catch-pan with a water-detector. The sump-pump has a water-detector next to it. And yep, the furnace has a water detector, alongside the condensate pump. One for the tankless water heater - even though it's outside. Easy. Driveway & landscaping slope away from the house? Yes. Properly sloped storm-water drains with clean outs? Yes. Leaf-shields & redundant gutter downspouts? Yes and yes.
- getpost 6y ago> I've had a flood from a broken washing machine hose before. Oh, me too! So far my only significant insurance claim, around $70K for repairs in the mid-90s. The leak occurred while the house was unoccupied for a week. Pro tip: you have to have receipts for all personal-property damage claims, which few people would or could have prior to everything being online. Exception: my insurer did accept a list of all damaged books with the associated cover price.
- DubiousPusher 6y agoLifesaver https://www.amazon.com/dp/B0748RK2XQ/ref=cm_sw_r_other_apa_i_foJfFbW3JCCSA https://www.amazon.com/dp/B0748RK2XQ/ref=cm_sw_r_other_apa_i...
- Symbiote 6y agoMany bathrooms in Scandinavia are "wet rooms", the floor slopes slightly towards one (sometimes two) floor drains. As I understand it, the building regulations say a washing machine must be in a room with a floor drain. Therefore, most washing machines are in the bathroom.
- mongol 6y agoThis used to be true, but today it is allowed to have a washing machine in a room without a floor drain, under certain conditions. There must be leakage detectors connected with mechanisms that can cut the water supply.
- pengaru 6y agoThe midwest home I grew up in, constructed in the 70s, had multiple drains in the basement floor which was also where the laundry hookups, wash basin, water softener, HVAC w/humidifier and air cleaner etc. were located. It was nothing special for the area. Homes out on the west coast are constructed much less robustly from what I've seen. I presume the mild climate has a lot to do with it.
- CalRobert 6y agoI was stunned to find out homes used to use panels of foamboard for sheathing aside from corners and one osb panel every 25 feet. Flimsy indeed.
- prawn 6y agoBoth bathrooms and the laundry in my house have floor drains. I can't recall seeing a house here in Australia that doesn't have drains in the wet areas actually - standard part of the plumbing that happens before the slab is poured.
- nickpp 6y agoI have floor drains in laundry room, bathrooms and water heater room. Good for peace of mind. But I hate how they dry out every couple of weeks and if I forget to refill them or we are away the sewer smell will raise...
- dmm 6y agoI think some people add a thin layer of cooking oil to rarely used drains so the water in the trap doesn't evaporate. I haven't had to try it myself but it's worth a try.
- eumenides1 6y agoUse mineral oil. Cooking oil goes rancid.
- rsync 6y ago"This house has a floor drain under the washing machine, with (as usual) the floor sloping towards the drain. Ditto for under the water heater." ... "I have never, ever seen this feature in any other house, and it costs next to nothing." ... I have some things to say about this ... It seems like an obvious win to put a floor drain in places that could potentially flood - especially the laundry room, but also (why not) bathrooms ... wouldn't it be great if a toilet overflow or a bathtub backup, etc., could be confined to that space ? It's a good idea, but there are some complications ... First, if it's a real drain, plumbed to sewer, then you need to keep it regularly watered - as in, pour a cup of water into it every day or three - or you will get sewer gas intrusion into the house (potential life safety hazard). The water in the trap will evaporate since the drain is never used so you need to keep it full. But if it's a real drain, the value has diminished since the backup might be below the drain and you flood anyway. So instead, you might consider draining to "daylight". This solves the trap/gas problem - you just drain to the outside. But, depending on your climate, this might be drafty - it is, after all, a 2" pipe. Finally, to make this work, you need to slope your tile which is either impossible, since perhaps the room already exists and is already tiled or adds cost and complexity to the new construction that is unexpected because, as you say, typical bathrooms and laundry rooms don't have floor drains. Here is how I solved this problem: 1. I tiled the bathrooms and laundry room with cove-base tile all the way around. These rooms are now 4" deep swimming pools. So I don't need any slope. 2. I installed a linear drain at the threshold of the room, right on the doorway line: https://www.schluter.com/schluter-us/en_US/showers/shower_with_linear_drain https://www.schluter.com/schluter-us/en_US/showers/shower_wi... ... usually you see these in showers, but it worked perfectly right at the door threshold, since you can cover the insert with the same tile that your floor is tiled with. 3. I didn't care about the draft or heat issues because I live in California. I simply capped the end of the pipe with screen for insects. However, if I lived in a different climate, or if I wanted to improve this design, I would consider placing a very sensitive (2-3 PSI) check valve at the end of the pipe. The drain would now be closed, but if the pipe fills with water (and you have 3-4 feet of elevation drop) then the check valve will open. More complexity, though ... This has all panned out well. The only minor item is that there is a very small gap between the door trim and the start of the linear drain but with some very careful caulking you can sort of "dam" that tiny spot to ensure the water gets to it if its coming along the wall.