2 ms·
That is indeed how things are traditionally done. I (along with Wheeler) am suggesting that division does not necessarily have to exist, and the control charts
by kqr 6y ago
That is indeed how things are traditionally done. I (along with Wheeler) am suggesting that division does not necessarily have to exist, and the control charts themselves can serve as useful feedback mechanisms. In many cases they may even be more effective than a PID controller, with zero tuning required.
As Wheeler notes in his article, PID controllers are based on the assumption that calibration/adjustments are free. As any practitioner of SPC knows, adjustments are never actually free in the face of natural variation in the process.