2 ms·
No, you are mistaken. CC plants have a steam bottoming cycle, but 2/3rds of the power comes from the combustion turbine front end. This gives them a very larg
by pfdietz 7y ago
No, you are mistaken. CC plants have a steam bottoming cycle, but 2/3rds of the power comes from the combustion turbine front end. This gives them a very large advantage over systems where all the power has to go through the steam. And simple cycle plants require no heat exchangers, steam cycle, or cooling water at all.