3 ms·
Sure, but to me this sounds scary. If I'd know that it were every "(2^32 - 1) ms to days" -> "49 days 17 hours 2 minutes 47.3 seconds" (millis stored in an uns
by qwertox 7y ago
Sure, but to me this sounds scary.
If I'd know that it were every "(2^32 - 1) ms to days" -> "49 days 17 hours 2 minutes 47.3 seconds" (millis stored in an unsigned long) then I'd be at ease, but 51 days doesn't say anything to me.
I just hope that they know why it's max 51 days.
- thr0w__4w4y 7y agoInstead of 1ms, try running the math if the tick rate instead was 1.024ms, (1024 usec). These things are often driven with a 32.768 MHz crystal, in case anyone's wondering why not just a nice even 1.000ms. On another forum I talked about way long ago, when I had to debug a huge system that reset after 248.x days of uptime. Yep, run the math...