4 ms·
>A commercially available N95 respirator requires a fit factor of 100 to be considered adequate in the workplace. The prototype mask achieved a fit factor of 67
by gruez 7y ago
>A commercially available N95 respirator requires a fit factor of 100 to be considered adequate in the workplace. The prototype mask achieved a fit factor of 67 for 1 author [...] The other 2 authors with LANL panel face size 10, the largest size, achieved fit factors of 13 and 17 by making the prototype mask inner layers slightly larger
So what's the actual effectiveness of this then? Does a fit factor of 67 mean your chances of getting infected (over what time?) is 33%? What about for the other two guys with fit factors of 13 and 17? I wouldn't risk a 87% or 83% chance of getting infected.
- subroutine 7y agoAccording to OSHA "Fit factor is a quantitative estimate of the fit of a particular respirator to a specific individual, and typically estimates the ratio of the concentration of a substance in ambient air to its concentration inside the respirator when worn." So I guess 100% would be like if the test aerosol had an ambient concentration of 100 µg/cubic meter, inside the mask the concentration would be < 1 µg/m3. 67% would be 33 µg/m3. Doesn't seem like a fool proof mask but there is prelim evidence that the initial virus load has an effect on symptom severity. If you could cut exposure to 1/3 i suppose that is better than nothing.