3 ms·
Power Analysis: A Complete Break of the KeeLoq Code Hopping Scheme (2008) [pdf]
- rini17 7y agoDifferential power analysis vulnerability is still pervasive. Why can't the CPU cut itself off and switch to internal power (supercapacitor) while it does sensitive computations? Even external switch+supercap potted together with CPU would be an improvement.
- nullc 7y agoOften using a magnetic probe is better than a current shunt in any case, due to power regulator noise. I can only imagine that shielding a device intended to be a radio transmitter would not be an easy proposition. :) Would it really be that much of an improvement to remove one vector when there is another equally good vector immediately available?
- rini17 7y agoIMO magnetic probe requires proximity - prying the package open instead of just measuring current from power supply (battery, USB). Is that equally good?