> and anything you can do without blowing that fuse won't damage the grid That's what you'd think. But I have actually done damage to the grid and had that fus
by jacquesm 7y ago
> and anything you can do without blowing that fuse won't damage the grid
That's what you'd think. But I have actually done damage to the grid and had that fuse still in one piece. I accidentally connected the -HV line of a neon light installation to ground. After I could see again I realized the power had gone out. I called my boss (landline still worked) who lived more than a kilometer away from the workshop and there too the power had gone out. It turned out my little accident had put a good chunk of the eastern part of Amsterdam out of commission and the fuse was just fine.
Fuses react to current, not to power and when you dump a high enough voltage back into the grid your fuse might not blow before you cause something further upstream to trigger to protect the rest of what's connected.
- madaxe_again 7y agoThis is exactly what RCDs are for - with a huge earth leak like that (and therefore L/N imbalance) it would have tripped within milliseconds, before cooking the grid. I am surprised by how infrequently they seem to be used outside of the U.K. - I’ve just rewired my house in Portugal as it was completely unearthed, and just had fuses, no RCDs.
- sib 7y agoFor those in the US, this is what's known as a GFCI (ground fault circuit interrupter).
- jacquesm 7y agoI'm not sure how common these are in an industrial setting nowadays, but back then all big electrical tooling would leak at least a little bit and if you hooked them up through ground fault interrupters those would trip all the time. A typical lathe, mill, plasmacutter or welder (which that particular workshop was full of) would be in the 10KW range with peaks far in excess of that during start-up. I don't remember if we had the office area (where I was working) on protected circuitry or not, that would have been an interesting bit of data. The building still exists, I'm almost tempted to go and have a look. That HV supply was a pretty beefy one by the way, the crocodile clamp that made 'first contact' was gone entirely.
- audunw 7y agoIt's required on all new construction in Norway for a decade or so as well. Very common for renovations as well. Norway also just switched to smart meters, which can detect ground problems as well, and supposedly a lot of issues has already been prevented by these being automatically reported. I suppose this is something which is more likely to spread to other countries, as it's not just a safety thing, but also an upgrade that makes your life more convenient, and saves the utilities money in the long term.
- foxrob92 7y agoRCDs are common in Australia. In Western Australia, whenever a house is sold it needs to have an electrical inspection which includes checking if there are enough functional RCDs. Not sure if that's a national requirement or not, but houses I've lived in in Victoria also had RCDs.
- ttsda 7y agoI live in Portugal and have RCDs in my (~7 year old) installation.
- mlindner 7y agoFuses or breakers? In the US everything is on individual breakers, but only bathrooms have GFCI (RCD) outlets.
- F_r_k 7y agoI'm sorry, but I don't believe one bit of your story. Ohm's law dictates that it's be impossible for your HV generator (neon transformer) to outpout a HV voltage when connected to the grid (you'd need thousands of kWs). Just impossible
- jacquesm 7y agoYou're more than welcome not to believe. Feel free to contact Riny Assink who was my boss / co-founder at the time for corroboration, I'm pretty sure he will remember because (1) it was a pretty memorable occasion in its own right, (2) the neon installation was intended to be used on a trade show the next day and my action meant we did not get to use one of our nicer eye catchers which really pissed him off, (3) he built the stuff that I blew up in the weeks leading up to the event, which pissed him off even more. I'm sure a bit of googling will turn up contact info for him. As for Ohm's law, when dealing with large transformers made for 50Hz dumping the full charge of a (pretty beefy) HV power supply into the low end of a circuit looks roughly like a lightning strike would, only with a much lower amount of Joules behind it. So it's not so much Ohm's law but Maxwell. Chances are some protection circuitry said 'better safe than sorry' and disconnected. FWIW when you receive a bit of data that contradicts your knowledge and assumptions in general the more interesting bits of knowledge are found by asking how things could have happened rather than to disbelieve a priori the facts as presented by eye witnesses. I have fuck all to gain from relating this story, and would happily stake my reputation on it being 100% the truth without any embellishment whatsoever. The whole reason I told it is because the person I replied to made roughly the same claim that you did. I agree that it should not be possible, and yet it happened.