3 ms·
Sometimes these factors of safety are matters of convention (like the discretion of a company of certifying engineer) and sometimes they are grounded in some sa
by bumby 7y ago
Sometimes these factors of safety are matters of convention (like the discretion of a company of certifying engineer) and sometimes they are grounded in some safety standard.
For example, if you're testing the integrity of a pressure vessel, the standard is to test it to 110% the rated maximum allowable working pressure if the medium is a compressible fluid (like air) or 150% if it's a 'non-compressible' fluid (like water, although everything is compressible to a certain extent). This is because the compression of a fluid stores a lot more internal energy if suddenly released. (Don't quote me exactly on these numbers because it's been a looooong time since I've had my nose in ASME standards)
- beerandt 7y agoI get factor of safety- (and phi etc for LRFD) what we're talking about is beyond the required factor of safety. OP designed the part using required multipliers, but the department checking the design wanted an extra 10% strength.
- bumby 7y agoThe point I was trying to get at is that in many cases (e.g., those not covered by an industry standard) there is no explicit “required” factor of safety. It’s left up to the discretion of the authority having jurisdiction. So while the design engineer may feel like a factor of safety of 2.0 is sufficient, the AHJ may “require” a 2.2 FOS to sign off