Wait, in the US you use 15A at 120v? Here in Europe (Spain at least) the typical is 16A at 240v. 1500W isn't that much of a problem. Oven breakers are even 20 o
by mcdevilkiller 7y ago
Wait, in the US you use 15A at 120v? Here in Europe (Spain at least) the typical is 16A at 240v. 1500W isn't that much of a problem. Oven breakers are even 20 or 32A.
- loeg 7y ago> Wait, in the US you use 15A at 120v? Here in Europe (Spain at least) the typical is 16A at 240v. Yep! The typical US residential circuit is only 120v, 15A breaker (so 12A at 80% load). (And that may be only 110-120v.) 20A circuits are also fairly common, but it's not the most common; the majority of wall outlets in a US house will be 15A. In this chart, https://en.wikipedia.org/wiki/NEMA_connector#/media/File:NEMA_simplified_pins.svg https://en.wikipedia.org/wiki/NEMA_connector#/media/File:NEM... , the commonly used US residential sockets are NEMA 5-15 (labelled "Typical Outlet," for 15A breaker circuits), NEMA 5-20 (for, duh, 20A breaker circuits), and NEMA 1-15 ("Old Outlet," in older buildings). > 1500W isn't that much of a problem. Oven breakers are even 20 or 32A. We do have higher amperage circuits for appliances like ovens and clothes driers, but they're usually dedicated circuits and have different socket shapes. You can see the labels "Clothes Dryer" and "Electric Oven" in the chart linked above :-).
- undersuit 7y agoComputer PSUs are generally more efficient at european electical standards. I read many a thread two years ago about cryptominers in America wiring our heavy appliance 220v lines into their racks to approach the efficiency that PSUs can reach at higher volts. And of course some datacenters just wire DC to the whole schebang instead of having an individual, well two redundant, PSUs per server.