3 ms·
A quick thought experiment... If you wanted to transfer 2MW, you could do it at 200 amps and 10,000 volts. Two 200 amp conductors, 3 meters long, and 10 mm^2
by londons_explore 7y ago
A quick thought experiment...
If you wanted to transfer 2MW, you could do it at 200 amps and 10,000 volts.
Two 200 amp conductors, 3 meters long, and 10 mm^2 cross sectional area will come out at half a kilogram. 400 watts of heating will happen in the wire, which could be cooled by a 1mm^2 water/steam cooling pipe running at 1 ml/sec. That weighs another 6 grams.
Insulating a 10,000 volt supply sounds a lot, but if the wire was insulated with PTFE, with a 10x safety margin, you would only need a thickness of 1mm on each conductor. Total weight 140 grams.
So - the total weight of a 2 Megawatt human-safe cable could, with the right engineering, be under a kilogram for 3 meters of cable, plenty to hook up your car or truck.
- baybal2 7y ago10kw? You will either need top tier, liquid cooled IGBTs or magnetics — both are not an option on a car. Maximum what FETs your money can buy can handle is 1500V. It's not them being that heavy, it's them being very stiff.
- MisterTea 7y agoIGCT's can handle a few kV and 1000's of amps. Plus you can setries them and increase the blocking voltage. Same goes for IGBT's, SCR's.
- MisterTea 7y agoMedium voltage charging isn't a big challenge considering some mining equipment is already powered by medium voltage. Those mammoth draglines and bucket excavators are powered by an actual high voltage extension cord that is moved around with the machine. They even have plugs and connectors, saw one rated for 25kV and 600A, three phase. That's almost 26MW. Totally doable.