If you're using DC to transmit the same amount of power, you'll probably be using similar voltages (otherwise you're going to need thicker cables). I suspect DC
by maxdamantus 7y ago
If you're using DC to transmit the same amount of power, you'll probably be using similar voltages (otherwise you're going to need thicker cables). I suspect DC is probably a greater fire risk in this case due to arcing. An arc is less likely to persist on AC since the potential keeps passing through 0 V (hence DC switches are designed to have a bigger air gap).
If it's just a matter of providing alternative circuitry for low-power devices, presumably you can already improve safety by just using lower-current circuit breakers.
- rodgerd 7y ago> If you're using DC to transmit the same amount of power, you'll probably be using similar voltages (otherwise you're going to need thicker cables). A good point - I guess I'm mostly thinking about the volume of things in the house that don't really need access to even a fraction of the 2.4kW available; having moved from incandescent bulbs to LEDs, I've got a bunch of unnecessary power supply and per-bulb transformers, for example.