I am not exactly sure what you imagine, but I (in Germany) have two 3 phase outlets (3x 16A @230V) in my flat and this is very common here. We use it for cook t
by atoav 7y ago
I am not exactly sure what you imagine, but I (in Germany) have two 3 phase outlets (3x 16A @230V) in my flat and this is very common here. We use it for cook tops and ovens in the kitchen typically, and it makes the difference between 15 mins for boiling water (old single phase cook top) and (on my induction cook top) 1 min.
Edit: and as an aside, why we probably don't do that everywhere: it makes for bigger plugs, and keeping safety standards can be a bit more expensive and space intensive with the potential 400V between phases.
- jws 7y agoWell that's news to me! I'm jealous. I'll bet you can preheat an electric oven in less than 20 minutes. I see the successor to the 16A Perilex connectors you are referencing is IEC 60309 which has an "extra low voltage" version with a smaller, 42mm diameter (1 2/3") plug good for 16A or 32A. 16A devices will fit in a 32A socket, but not the other way around. So that seems to be a 1.3kW and 2.6kW solution. Sign me up!
- KaiserPro 7y agoUK here: We don't have three phase (well its not common) but we can heat an oven up to 220c(420f) in 7 minutes. I think its a 3kw oven. its on a 32 amp (isolated) breaker.
- atoav 7y agoHad something to toast so I tested mine too (3x 16A @230V). Took 4:52 to heat up to 220°C
- benj111 7y agoI've never ever seen it in the UK, but I did live in a house with a flat on a separate meter, that as it turned out was on a separate phase. I only discovered this because there was a fault on the line for only one phase, and only after checking and changing every fuse (wire), and unplugging every electrical item. Grr.
- benj111 7y ago"So that seems to be a 1.3kW and 2.6kW solution" Germany is 230v so that would be more like 3kw and 6kw. I'm in the UK (also 230v) and a standard outlet can do 3kw, I think fuseboard fuses are 32amp so I don't know if 6kw is a practical upper bound though (edit: On 2nd thoughts I'm not even sure this is relevant to 3 phase).
- fyfy18 7y agoPedantic: Standard outlets are 16A in mainland Europe, so 3.7kW. Modern single ovens can also be connected to a standard single phase outlet rather than a dedicated circuit. In my kitchen the induction cooktop is on a 16A three phase circuit, and all the other outlets (fridge/freezer, oven, dishwasher and appliances) are on a 16A single phase circuit. 5:11 from 20°C to 220°C
- benj111 7y agoWouldn't pedantic be 3.68kw? I've never actually come across anything higher than 3kw, also a 16amp fuse isnt that precise, you could probably get up to 20 amps without it failing. The hotter you run it the quicker it fails though, so if you're regularly running 3.7kw through a 16 amp fuse, you may well find it failing, not through an underlying fault of anything plugged in to it.
- xxs 7y ago>I think fuseboard fuses are 32amp Most cables are 16A, so the outlets are 16A as well. Also UK uses 240V, not 230V. 32A circuit breakers would make the cables burn when overloaded.
- benj111 7y agoFlex cables might be 16amp, individual sockets are 16 amp though, so if you have more than one of those on a ring main... "Use a 30amp fuse or 32amp MCB for larger radial circuits, ring circuits up to 100m, cookers and electric showers up to 7200W" http://simplifydiy.com/electrical/basic-electrics/fuses http://simplifydiy.com/electrical/basic-electrics/fuses
- alexdumitru 7y agoI'm in Romania and it heats to 180C in about 3 and a half minutes.
- makomk 7y agoI think Germany is one of the few countries which bothers to wire up three phase power to ordinary houses, not sure why.
- ahje 7y agoIt's quite common in the Nordic countries as well.