Type F and E plugs in Europe have the same safety as the UK plug but they are less bulky. The reason why F and E have similar safety but don't require fuse as
by nabla9 7y ago
Type F and E plugs in Europe have the same safety as the UK plug but they are less bulky.
The reason why F and E have similar safety but don't require fuse as UK plugs have is the use of ring circuits in the UK.
- masklinn 7y ago> Type F and E plugs in Europe have the same safety as the UK plug but they are less bulky. I don't know that they're exactly as safe as UK plugs, though they're not far: all three designs ensure the plug is earthed before the "power" pins make contact, but historically UK plugs require an earth pin to be inserted before opening the "power" pin shutters while in type E/F it's just the insertion of the power plugs which force the shutters open. Type E/F plugs also use recessed sockets rather than insulated pin roots but that should not make a difference.
- tomatocracy 7y agoCertain designs of UK extension strips are small/'not tall' enough to allow a plug to be inserted upside down with only the earth pin in, opening the shutters without anything blocking them. This is a potential safety hazard when you consider this is something children might do without knowing the danger. This type of design is technically not to spec but widely sold eg by IKEA. A recessed design means this isn't possible so is safer as this type of misspecification isn't possible.
- Someone1234 7y agoF and E don't have switches on the wall, and don't have the same shutter-safe design. They're likely closer than some even worse plugs, but the UK plug (aside from bulk/cost) really is the safest plug in the world.
- welterde 7y agoThe sockets are however not recessed making them less safe than type E and F as it now becomes possible touch the the live conductor if the insulation at the base is damaged (or is completely absent for some cheaper cables).
- Someone1234 7y ago> now becomes possible touch the the live conductor if the insulation at the base is damaged If the UK plug isn't pushed all the way in the contacts aren't live. So, nope. The insulation is an extra safety measure on an already over-engineered plug.
- welterde 7y agoThat's not actually true. The pins mate on the side and have quite a bit of play when they make contact (otherwise the connection would be quite unreliable and might even be a fire-hazard). The insulation is _not_ an extra safety feature.
- masklinn 7y ago> F and E don't have switches on the wall That seems completely independent from the actual plug design. You can certainly get sockets with switches[0] it just isn't very popular (or, frankly, useful). > and don't have the same shutter-safe design. What you're saying is a bit unclear, do you mean the part where UK plugs need some sort of earth inserted to open "power" shutters or do you mean having shutters at all? Because the latter is definitely the case, and as an other commenter notes there are widely available plugs which can be inserted "inverted" and open the powered shutters with little efforts. While the E/F design is "less safe" in the best case scenario it's also less conducive to easy misuse. [0] https://www.amazon.de/dp/B000ONWKXS https://www.amazon.de/dp/B000ONWKXS