In France only few people have 3 phases. But I think the a reason why high power appliances are more common in Europe is simply because the voltage is higher.
by GuB-42 7y ago
In France only few people have 3 phases.
But I think the a reason why high power appliances are more common in Europe is simply because the voltage is higher. Double the voltage means you can pass double the power over the same wires.
- masklinn 7y agoYeah. Electric kettles are fine instruments in europe while they're infuriating in the US. That's not always a pure positive though: as kettles work fine I've never seen a thermo pot in europe.
- user5994461 7y agoIn France, old houses have 3 phases. There are 3 phases going into the house from the street poles, and you can catch them at some plugs in the house depending if and where they were wired to (the only home appliance that can use 3 phases is electric stoves). This used to be the "standard" setup until somewhere in the 20th century when it changed to single phase. Now there is only one phase going to homes.
- GuB-42 7y agoI remember my grandfather who was a carpenter. He had a 3-phase woodworking machine in his garage. It was in the late 80s. He needed a special installation for it, and possibly a more expensive subscription. He later changed it for a single phase machine, partly for that reason. And then he moved, and he now has only one phase like everyone else.
- stetrain 7y agoMost US houses have 240 (by combining two offset phases of 120v) but that is generally only available at special plugs installed for the range/oven and clothes dryer, not throughout the house.
- alerighi 7y agoNowadays with devices with switching mode power a lot of appliances even sold in the US can accept voltages in the range of 100-240V, and typically these power supplies are more efficient if they are run at 240V. Why in new installations in the US homes don't you put 240V outlet everywhere? For me it would make sense to do that, for example if you have to plug in a computer, or TV, or practically everything modern.
- realityking 7y agoBecause any appliance that isn't build for 240V would break, if not hurt/kill you when powered with twice the voltage it was designed for.
- Gibbon1 7y agoAs well the long trend in the US is for devices outside the kitchen to use less power. Whens the last time you overloaded a breaker in a bed room?
- magduf 7y agoI used to do it all the time, just by running my laser printer. I was in an old house that some amateur must have wired, so all the power for the entire second floor, plus both bathrooms, plus all the lights on that floor, were routed through a single GFCI outlet. It would pop every time I ran the laser printer, but only the first time. After I reset the breaker (in the dark, because the lights would go out), I could try printing again and it wouldn't pop that time.
- magduf 7y agoWell presumably, they'd change the outlets to 240V-specific outlets. We already have NEMA outlets for 240V single-phase applications, even in residential buildings. Of course, then you'll have the problem where someone moves into a new house and then they can't use any of their stuff because it doesn't fit into the outlet. Then they'll go to Home Depot and buy an adapter, which just converts the physical outlets (and has a big warning about not using for devices not rated for 240V), and use that with their heater or toaster or vacuum cleaner, and start a fire that burns down an entire apartment complex.
- magduf 7y ago>Double the voltage means you can pass double the power over the same wires. Wrong. It means you get 1/4 the resistive loss (in the wires) for the same power. So you can pass 4 times the power over the same wires if you want.
- MertsA 7y ago>It means you get 1/4 the resistive loss (in the wires) for the same power. So you can pass 4 times the power over the same wires if you want. Wrong. P = VI and resistive losses are RI^2. For double voltage at the same power then yeah, R(I/2)^2 = 1/4 * RI^2. For double the voltage but 4 times the power then 4P = 2V(x*I) so x=2 and we square that so it's 4 times as much resistive losses. You can double the power if you double the voltage and keep the same resistive losses. The parent comment was right. >It means you get 1/4 the resistive loss (in the wires) for the same power. This is correct, but it scales with the square of the current, so you can't just extrapolate it linearly like that.