Steam turbines have row after row of blades, each successive blade wheel larger and lower pressure than the last. Exit temperatures from modern turbogenerators
by Animats 7y ago
Steam turbines have row after row of blades, each successive blade wheel larger and lower pressure than the last. Exit temperatures from modern turbogenerators are around 120° C, where the steam is about to turn into water, and pressure is usually below atmospheric. Almost all the energy which thermodynamics permits to be extracted has been extracted.
- taneq 7y agoI probably should have phrased it better - I was picturing [Furnace] | [Thermophotovoltaics] | [Boiler], so the PV part gets first crack at the light/IR from the furnace and then the boiler cools the PV gear as it boils the water. This is also how it's suggested to be used in a paper linked elsewhere in the discussion above: https://www.sciencedirect.com/science/article/pii/S0306261912000554 https://www.sciencedirect.com/science/article/pii/S030626191...