3 ms·
While you're right that 5000 W is only 1.2 kelvin liters per second on water, typical shower flow rates are about 8 ℓ/minute, 133 mℓ/s in SI units, and at that
by kragen 7y ago
While you're right that 5000 W is only 1.2 kelvin liters per second on water, typical shower flow rates are about 8 ℓ/minute, 133 mℓ/s in SI units, and at that flow rate you get about 9°C of heating. This may be a reason electric showers are more popular in tropical countries like Brazil, Perú, and Costa Rica: ΔT = 9° gets you from 28° to 37° just fine. And you always (well, usually) have the option of lowering the shower flow rate to get a wimpier flow of much hotter water.
- cesarb 7y ago> And you always (well, usually) have the option of lowering the shower flow rate to get a wimpier flow of much hotter water. Don't overdo it; when I was a child, I burned a shower head by doing exactly that (lowering the flow to get hotter water).
- pdonis 7y ago> typical shower flow rates are about 8 ℓ/minute This is a fair bit slower than a typical US flow rate (which is about 5 gallons/minute or about 20 liters/minute). So yes, with a slower flow rate and hotter water to begin with I can see it being usable.