Professional setup has much tighter tolerance than 3dB. I was using 6dB as an example. Usually you're trying to kill peaks that are 10-20dB over. This kind of
by bravo22 7y ago
Professional setup has much tighter tolerance than 3dB. I was using 6dB as an example. Usually you're trying to kill peaks that are 10-20dB over.
This kind of debugging is very routine. You do it manually with E/H field probes and a spectrum analyzer in between lab visits. This setup makes it more repeatable by automating it.
- xondono 7y ago>Professional setup has much tighter tolerance than 3dB. To comply with CISPR (as an example), a lab only has to validate <4.5dB (in the 30 MHz to 300 MHz range), and up to 5.2 dB (from 30 MHz to 1 GHz). See for instance [1]. By the way, if you are doing this kind of testing routinely, you need to check your PCB layout process. This fine grained tweeting should be a last resort option. [1]http://ing.univaq.it/emc-chap-it/download/MUinEMC_Revision%20of%20CISPR%2016-4-2%20doc.pdf http://ing.univaq.it/emc-chap-it/download/MUinEMC_Revision%2...