4 ms·
Does this ever get bad enough to feel without touching something else to directly complete the circuit? I would predictably get this when using laptop (on lap)
by mindslight 8y ago
Does this ever get bad enough to feel without touching something else to directly complete the circuit?
I would predictably get this when using laptop (on lap) and resting my arm on a metal heater next to me. I ended up returning a few AC adapters because the leakage was too damn high, and eventually they offered me a three prong version that came with many more regulatory marks.
The problem with two prong devices is that a designer has to assume either wire could be hot, because it could be plugged in backwards. I've got to wonder if a change in the regulations that would allow for a single cap to the probable neutral could solve this. It would double the leakage current if the thing were actually plugged in backwards, but as long as it was just more uncomfortable rather than dangerous this would be a win.
Also there are a few handwavey things at the bottom of the post that just leave me scratching my head:
> Even though the MagSafe power supply itself is not connected to the mains earth, there is just enough inductance leakage for the floating charge to dissipate through the plastic sheath of the mains cable.
There could be something to what is being said, but if there is he's not describing it well.
> It's worth noting that the fuzzy-electronics effect can be felt if you use an earthed power point but the power point's Active and Neutral are wired back to front
That's an odd diagnosis, because three prong means the output is being directly grounded. Instead, I would infer that the ground (EGC) was disconnected (like say an old home where someone improperly changed two prong to three prong outlets when remodeling).