5 ms·
Note that diesel generators have the counter intuitive property of using more fuel at 50% of max load than at 80% of max load. Most other power generations have
by bluGill 8y ago
Note that diesel generators have the counter intuitive property of using more fuel at 50% of max load than at 80% of max load. Most other power generations have some variation of this where operating a 80-90% of max power is where they are more fuel efficient. Thus even for conventional generation battery backup on the grid has the potential to save money.
- thedrbrian 8y agocitation needed. I could see an engine using more fuel per unit power at a lower power level but not less fuel overall. If they did you would just run the engine at 80% all the time and waste the excess in a massive water brake or resistor bank.
- brianwawok 8y agoI am sure it is per unit. Means you are better off to run it at high load and battery the excess power, then shut the whole thing off for a bit, vs run it at 50% all the time.
- cryptonector 8y agoIf you have two engines you could be running at 40% each, or shut one down and run the other at 80%, it will be more efficient to do the latter (unless you have to be able to start the idle one quickly and that's not possible if it's at 0%, so then you run one at 75% and the other at 5%).
- crushcrashcrush 8y agoEngines are simple pumps that operate most efficiently “fully open”
- RandomBacon 8y agoI don't know about using more fuel at 50%... They are however, are more efficient around 70% load than 50% load.
- D_Alex 8y agoIn diesel engines the power generated is directly controlled by the amount of fuel delivered - if you want more power, inject more fuel. Unlike most spark ignition engines, there is no throttle valve, you control the stroke of the diesel pump (or the time the injectors stay open in common rail engines). So it is completely wrong to say that they use more fuel at 50% load than at 80%.