Electricity conversion: pretty darn efficient. Conveying the heat from a brake to a building: not so much.
by kazinator 8y ago
Electricity conversion: pretty darn efficient.
Conveying the heat from a brake to a building: not so much.
- postalrat 8y agoYou either live in a warmer climate or don't have electric heat.
- VBprogrammer 8y agoConveying mechanical energy: reasonably efficient over modest distances. https://www.lowtechmagazine.com/2013/03/the-mechanical-transmission-of-power-3-wire-ropes.html https://www.lowtechmagazine.com/2013/03/the-mechanical-trans...
- kazinator 8y agoAre you proposing some sort of chain, belt or shaft drive, such that the brake is actually housed inside the building?
- VBprogrammer 8y agoYes, that's what I was getting at. You can have the windmill located on a high point on the property (or just far away enough to be out of the way) then convey that energy back to near the house and use a brake to generate the heat near where it is needed.
- Someone 8y agoAt small scale, why wouldn’t it be efficient? You can use the windmill to also drive a pump that pumps the water through, say, 20 meters of well-insulated pipe and from there through your floor heating system. Also, https://en.wikipedia.org/wiki/District_heating https://en.wikipedia.org/wiki/District_heating is at least somewhat competitive with other methods, so scaling up may be possible, too.
- seanalltogether 8y agoYeah, this article seems like bad engineering, especially when the opening paragraph is trying to compare mechanical energy to solar heat. A windmill with a generator inside it that is hooked to a wire that drives an electric heating element inside your house will be more efficient then a water break inside an insulated chamber that pushes hot water through tubes into your home.
- JoeAltmaier 8y agoUntil it breaks down? The water+tubes is a low-tech solution that will survive the apocalypse.
- kazinator 8y agoFirstly, are you proposing that people should have windmills that have no generator at all, only a brake for generating heat? If we already have electric generation and conveyance in the picture, then the pump and tube system is additional. Electric generation and conveyance is "low tech": we've had it for over a hundred years now. It has few moving parts. Pipes can leak. The fluid needs to be drained and replaced. the system needs to be bled. Pumps break; seals wear out, and such.
- kevin_thibedeau 8y agoFew moving parts but many electronic components that will fail eventually.
- ip26 8y agoWait, by "water" did you mean "electrons" and by "tubes" you meant "wires"? Electronics can get phenomenally complicated, but electricity itself can be pretty fantastically simple. There's no such thing as electrons leaking out of a poorly sealed wire onto your floor, for example, and you'll never accumulate sediment and corrosion inside your wires...
- lscharen 8y ago
- Spooky23 8y agoThis gets thrown out on HN often about any topic regarding heating. There's a reason why nobody in cold places has electric heat or air heat pumps -- they are either too expensive or not effective enough to run. It sounds like air-to-water pumps may offer a new alternative, but it's still more expensive than gas in many scenarios.
- freeone3000 8y agoMontreal, and the rest of Quebec, uses electric heating, because electricity is cheaper than gas here (due to the hydroelectric dams along the st lawrence). There are regions electricity is cheaper than gas.
- aoner 8y agoWe ditched our gas and have an air to water heat pump, costed around €6000 ex subsidies (I live in Amsterdam so not the coldest weather, we also have solar thermal and PV). However air to water heat pumps are also applicable in cold climates. If you're interested here is an example datasheet[1] of an air to water heat pump (2018) (using Celsius here): Mitsubishi PUHZ-SHW112YAA Guaranteed operating range (outdoor): Heating: -28 to +21 Domestic hot water: -28 to +35 On page 108 you can find the actual co-efficient of performance (COP) for different outside temperatures and inside water heating temperatures. As an example: at -10 and an water temperature for heating at 25 you still get a COP of 3+. That means that 100% electricity moves 300% of heat into your house. [1]: https://www.mitsubishi-les.info/database/servicemanual/files/201803_ATW_DATABOOK.pdf https://www.mitsubishi-les.info/database/servicemanual/files...
- kazinator 8y agoHow is electric expensive, if you're getting electricity for free from your wind turbine? No matter in what form you get energy out of it, it's about the same, modulo efficiency. Effective? A watt is a watt. A heater putting out 2000 watts of heating intensity is exactly as effective whether it runs on electricity, nuclear fusion, or burning dried unicorn poop. Some electric heaters (like baseboard units) don't circulate air very well. They sometimes get installed under windows and basically just move hot air toward a cold window. If we take that to represent all manner of electric space heating, that is a strawman.
- severak_cz 8y agonote that heat is already transported from one building to another when using central heating. For example - Prague is (partly) heated by waste heat from Mělník power plant.