2 ms·
I'd be more worried about skew. CAT5e and 6a seem to have the same delay skew spec, and I can easily imagine Ethernet PHYs that are simply unable to operate be
by amluto 8y ago
I'd be more worried about skew. CAT5e and 6a seem to have the same delay skew spec, and I can easily imagine Ethernet PHYs that are simply unable to operate beyond 100Mbps with out-of-spec skew.
CAT7 seems dubious (not recognized at all by everyone in the industry) but has a tighter delay skew spec, so this would help.
Another potential issue would be if the PHY has an equalizer that can handle reflections due to not-quite-perfect termination at 100m or closer but has trouble beyond 100m.
Something like a 1000BASE-T-LR or something that just means "1 Gbps over CAT [whatever is needed] if properly installed at lengths up to 200m" would be quite nice. Most likely a lot of equipment would meet that spec out-of-the-box.