3 ms·
> A heat-sensing infrared detector monitored the terrace, > but he approached it slowly from behind a large, > homemade polyester shield. The low ther
by DJN 16y ago
> A heat-sensing infrared detector monitored the terrace,
> but he approached it slowly from behind a large,
> homemade polyester shield. The low thermal
> conductivity of the polyester blocked his body heat
> from reaching the sensor
"Out of the box" thinking at its best.
> An automatic electric pulse constantly shot into the
> room and back out along these wires. If any of the
> sensors were tripped, the circuit would break. When a
> pulse shot into the room, it expected an answer. If
> it didn't get one, it activated the alarm.
> Once the copper wires were exposed, he clipped a new,
> precut piece of wire between the inbound and outbound
> cables. This bridge rerouted the incoming electric
> pulse over to the outbound wire before the signal
> reached the sensors. It no longer mattered what
> happened further down the line. The sensors were out
> of the loop. It was now safe for the others to enter.
In hindsight it seems like sending pulses with different signatures down each channel would have fixed this problem. I wonder how many sensors out there are infected with this bug.