3 ms·
TL;DR Possible fault in an onboard MEMS oscillator from helium exposure. https://file.scirp.org/pdf/JST_2013122009560886.pdf https://file.scirp.org/pdf/JST_201
by toomuchtodo 8y ago
TL;DR Possible fault in an onboard MEMS oscillator from helium exposure.
https://file.scirp.org/pdf/JST_2013122009560886.pdf https://file.scirp.org/pdf/JST_2013122009560886.pdf
> Exposure of absolute pressure sensors, resonant microtube density, binary concentration sensors and chip-scale vacuum
packaged pirani gauges to room temperature helium resulted in a gradual drift in sensor output. No effect was found for
differential pressure sensors and pirani gauges vacuum packaged with ceramic or metal packages. The observed results
apply to other vacuum packaged MEMS devices such as gyroscopes, voltage controlled oscillators, infrared and Coriolis
mass flow sensors. Potential causes for this loss of hermeticity are discussed as well as application limitations for
MEMS sensors.