3 ms·
> finally, ECC is a bit useless if your whole drive or device fails, which is a much more common failure mode. I'm not sure that this is true. Almost all the p
by toast0 8y ago
> finally, ECC is a bit useless if your whole drive or device fails, which is a much more common failure mode.
I'm not sure that this is true. Almost all the platter based drives I've had fail gave some amount of warning signs before they became completely inaccessible. (The exception that I can remember was the one I damaged the circuit board of with a wrong type screw). My personal experience is just anecdotes, but we had a couple thousand disks at work that I managed, and we ended up swapping about one disk a week. SMART defect counts were very predictive of future disk failures, although even then the disks would usually be partially readable.
SSDs on the other hand, the failure rate was much lower, but the failure mode was always disk disappears from the bus. We could never figure out a way to predict that (our write volumes aren't very high). Occasionally we'd see a large increase in defect count and slowdown in access for a while as a drive would reallocate a large block, but if we waited for it to settle, everything would be fine after.