7 ms·
Tiny bit of history: The reason plugs in the UK are so big is that each one must be individually fused. And the reason for that is something called a "ring cir
by ars 16y ago
Tiny bit of history:
The reason plugs in the UK are so big is that each one must be individually fused. And the reason for that is something called a "ring circuit".
In a ring circuit you have, say, a 40 amp fuse at the mains/box. From this you send out two wires, each rated only for 20 amps, going in a circle around the house. You can now supply 40 amps worth of power using only cheaper 20 amp wires. (Since the current can flow over both wires at once.)
But this means that the wires going to an individual appliance are far too small for the main breaker, so each appliance gets a fuse in the plug.
Ring circuits have serious drawbacks, but they helped during a time when there was a copper shortage.
And ever since then the UK has been stuck with huge plugs.
- nodata 16y agoInteresting. What other serious drawbacks do they have? Any other countries use them?
- junglefever 16y agoI think that Singapore use the same plug.
- prawn 16y agoHong Kong sometimes too.
- masklinn 16y ago> What other serious drawbacks do they have? They tend to rest on the plug's back, and hurt a lot when you step on them. > Any other countries use them? India and South Africa use the so-called Type D plug[0] (also called Type M in its 15A incarnation), which is similar but uses round plugs (type D is actually an older english standard). Some other south-east asian countries also use Type D. The english plug is called "Type G" and used in a number of former colonies and protectorates[1], especially in Africa and the Middle East. [0] http://en.wikipedia.org/wiki/AC_power_plugs_and_sockets#Type_D http://en.wikipedia.org/wiki/AC_power_plugs_and_sockets#Type... [1] http://en.wikipedia.org/wiki/AC_power_plugs_and_sockets#Type_G http://en.wikipedia.org/wiki/AC_power_plugs_and_sockets#Type...
- confuzatron 16y agoSince you're calling it the English plug, I should mention that they also use it in Wales, Northern Ireland, and Scotland.
- KoZeN 16y agoIreland also use them.
- ajb 16y agoThis is all true, but it doesn't explain why they have to be shaped like a caltrops. I wish someone would come up with a design which doesn't hurt so much when you accidentally tread on one.
- teamonkey 16y agoI think that's simply so that the wire runs parallel to the wall instead of sticking out at 90 degrees. Without a movable part it's hard to have one feature without the other.
- stuhacking 16y agoThis is a common complaint. I wonder where people are leaving their unused plugs that they constantly tread on them? Probably not in a storage box/drawer.
- andrewingram 16y agoThis image of the first prototype shows that the need for an individual fuse has been designed for: http://www.minkyu.co.uk/Site/Product/Entries/2009/4/20_Folding_Plug_System_files/Image-3.ashx.jpg http://www.minkyu.co.uk/Site/Product/Entries/2009/4/20_Foldi... The promo shots of the final working model don't show how you get at the fuse, but I'd be very surprised if it has been overlooked. I suspect it's something to do with the red dots.
- masklinn 16y ago> The promo shots of the final working model don't show how you get at the fuse, but I'd be very surprised if it has been overlooked. I suspect it's something to do with the red dots. Indeed, the red dot is the plug cover. This set of blogspam pictures don't show it, but previous sets (the folding plug first made rounds in mid-2009) showed how the plug works. You can see an "action shot" simulation of the plug in the video: http://www.youtube.com/watch?v=f6DvjKkGT6s#t=1m46 http://www.youtube.com/watch?v=f6DvjKkGT6s#t=1m46
- points 16y agoThat's not really fair. Given a choice between US plugs (spark, fall out of sockets, flimsy, dangerous, bendy pins), and UK plugs (Built to last, don't spark, fused, solid) I know which I'd choose. There's also large advantages to having each plug individually fused - individual appliances blow rather than the whole circuit. So I wouldn't say we're "stuck with huge plugs". The only real time it's a slight issue/pain is when you go on a plane and the cables take up a bit of space.
- JoeAltmaier 16y agoWow, so self-delusion is alive and well in the UK! "The only time its a slight issue"??? How about manufacturing, shipping, selling, storing, repairing, and paying for that overdesigned eyesore? How about looking at it? How about moving the couch out from the wall so the dang thing will fit back there?
- points 16y agoThose are all minor inconveniences compared with: * trip up a cable, and the plug falls out of the wall (Pulling a UK plug out required force. It will not pull out) Plus the cable exits a plug pointing downward, which means it will not pull out via the cable. * Sparks when you put a plug in or out. * Bent pins that look like they're about to drop off * No shielding on pins * Often no mechanism to stop things being put in sockets (All UK sockets only open once an earth pin has gone in I wonder what the incidence of electrocution is in the UK vs US. I'm probably biased, but I certainly feel far safer here, especially having kids.
- JoeAltmaier 16y agoTrip on the cable, and the lamp falls off the table? Better? "Sparks"? Are you kidding?
- points 16y agoLamps seem very prevalent in the US. Why do most apartments I've been in not have ceiling lights? WTF? When I lived in the US I'd go in a room and spend a while finding 4 lamps and turning them on. Same in hotels. Also, when you decide to put a lamp somewhere, you typically make sure the cable is not somewhere that can be tripped up. But as I say, all rooms in the UK come with a fitted ceiling light, and a light switch by the door. So lamps are less common.
- tel 16y agoWhy not have socket fuses like you can find in bathrooms sometimes? I'm not arguing history, instead I'm just curious if there's some latent advantage to putting that hardware into the plug. All I can see are losses in convenience, duplication of effort, and weakened robustness.
- almost 16y agoDifferent plugs will have different fuses appropriate to the type of device. I have no idea how much of a benefit this is but you couldn't do that if the fuses were in the socket.
- lutorm 16y agoWhy would 2x20A wires use less copper than a 40A one? Current capacity is a function of the cross-sectional area. Or did you mean that you only need to run one set of wire instead of multiple ones to multiple outlets?
- ramchip 16y agoAccording to (http://www.faqs.org/faqs/electrical-wiring/part1/section-20.html http://www.faqs.org/faqs/electrical-wiring/part1/section-20....) and to the wiki article on wire gauges, 40A requires 8-gauge wire, which is 3.264mm in diameter, while 20A is 12-gauge, which is 2.054mm. The ratio of their cross-sectional area is 2.53; this justifies that the 40A wire conducts twice as much as the 20A but has 2.53 as much area, thus being more costly. I'm not sure why. Is the skin effect sufficient to explain this?
- mturmon 16y agoSkin effect is not a factor in 12AWG wire at 60Hz. It takes much higher gauges and/or higher frequencies.
- regularfry 16y agoI doubt it's skin effect. More likely to be a safety margin so that it doesn't risk overheating.
- kjuhygtfrde 16y agoYes, a ring circuit you run a single wire around the room and back to the fuseboard. With a spur circuit you run a single wire to the furthest plug. In a typical room going back to the fuseboard isn't much further so it's not twice as much wire - more like 10% more
- castis 16y agoIts my understanding that their electrical outlets are designed similar to a token ring network setup. That uses way less cabling than any other network.
- cstross 16y agoThere's also a second reason British plugs are robust and fused: they're built to carry up to 3 kilowatts at 230 volts. (None of your wimpish American 110 volt mains juice here! Nothing quite makes your hair stand on end like accidentally touching a live pin carrying 230 volts and 13 amps ...) To that end, the live and neutral contacts in a British socket are shuttered. The long earth pin on the plug makes contact before the live or neutral pins are in the socket, and once in contact, raises a shutter to permit live and neutral to make contact. And the nether regions of those pins are insulated so that if a plug is halfway into a socket and something bridges the pins, it can't make contact. This is a great design -- for space heaters and ovens and server racks. It's a bit less useful for the low power consumption devices that have come to dominate the market (where maximum draw is well under 1Kw -- often under 0.1Kw).
- camtarn 16y agoIt does, however, mean that any type of appliance that you might wish to plug in uses the same plug, regardless of what power level it wants - quite a good example of It Just Works, even if the price you pay is huge plugs. Of course, that does break down a bit when you get to fuses, since you now have to worry about using different capacity fuses for appliances with different expected maximum power draw (3A for most things, 5A for the odd high-power small appliance, 13A for anything involving a heater...)
- rg 16y agoActually, UK buildings typically contain at least three different standard sockets and plugs--the big ugly ones (with a supply of four different fuses needed), a mini version of that design commonly used for table lamps and floor lamps, and a third design allowed in bathrooms so you can plug in an electric shaver (electrical sockets and even light switches are ordinarily barred from bathrooms). There are also many different kinds of lightbulbs (screw-in, push-in, push-and-turn-to-lock-two pins) in many different physical sizes (as well as different wattages). Running a family house requires a considerable stock of bulbs and fuses, which explains all the "electrical supplies" shops which are unknown in the US. Up until about 10 years ago, in my personal experience, UK small appliances, lamps, etc. were sold with bare AC wires and the householder was expected to add the needed style of plug; now everything comes with the huge plugs.