I tried to look this up, info here: https://www.dni.gov/files/NCSC/documents/Regulations/Technical-Specifications-SCIF-Construction.pdf https://www.dni.gov/file
by PowerfulWizard 8y ago
I tried to look this up, info here: https://www.dni.gov/files/NCSC/documents/Regulations/Technical-Specifications-SCIF-Construction.pdf https://www.dni.gov/files/NCSC/documents/Regulations/Technic... (Ch. 3 sec. F, pg. 13)
F. SCIF Window Criteria
1. Every effort should be made to minimize or eliminate windows in the SCIF,
especially on the ground floor.
2. Windows shall be non-opening.
3. Windows shall be protected by security alarms in accordance with Chapter 7 when
they are within 18 feet of the ground or an accessible platform.
4. Windows shall provide visual and acoustic protection.
5. Windows shall be treated to provide RF protection when recommended by the CTTA.
6. All windows less than 18 feet above the ground or from the nearest platform
affording access to the window (measured from the bottom of the window), shall be
protected against forced entry and meet the standard for the perimeter.
- kryogen1c 8y agoBeat me to it. https://en.wikipedia.org/wiki/Sensitive_Compartmented_Information_Facility?wprov=sfla1 https://en.wikipedia.org/wiki/Sensitive_Compartmented_Inform...
- nickpsecurity 8y agoThere's also the room in a room concept where one is suspended inside the other. You might add things like ultrasound masking or blocking, too, since it was a known attack vector. From there, I thought about, but can't recall if implemented, some double doorway with buffer in between so opening a door didn't leak sounds/signals. Open one, go in, close it, and then go through other.