3 ms·
Battery capacity scales with volume, whereas external heating/cooling losses to the environment scales with surface area. That means, for any large enough scal
by londons_explore 8y ago
Battery capacity scales with volume, whereas external heating/cooling losses to the environment scales with surface area.
That means, for any large enough scale plant, the cost to keep it at a fixed temperature diminishes to insignificant.
- woodandsteel 8y agoCorrect, and you can add arbitrarily thick insulation.