2 ms·
Fascinating! That's an off-the-shelf SLA (sealed lead acid) battery like many UPS/alarm systems use, which need replacement at least every 3 years (or much soon
by ck2 16y ago
Fascinating! That's an off-the-shelf SLA (sealed lead acid) battery like many UPS/alarm systems use, which need replacement at least every 3 years (or much sooner if they are deeply discharged).
But I would happily pay $2, even $5 more for that feature on a motherboard.
- borism 16y agoit seems to be connected directly to PSU?
- slug 16y agoFrom the article, the motherboard only requires one 12V input only, instead of the usual array of voltages (+-5, +-12, +3.3, etc). Having charging circuitry to keep the battery operational (trickle charge) and being able to provide power to the motherboard when mains power fails is mostly straightforward and cheaper in this case. Not much different from what you would find on a regular UPS, but removes a few conversion steps - (DC 12V) ->(110/220V AC)-> DC - improving efficiency and reliability.