3 ms·
FWIW utility generators are cooled with hydrogen to reduce windage losses and promote cooling. Hydrogen is probably lower viscosity and higher thermal conductiv
by HankB99 8y ago
FWIW utility generators are cooled with hydrogen to reduce windage losses and promote cooling. Hydrogen is probably lower viscosity and higher thermal conductivity than helium. It's also very hard to contain due to the small molecular size and has the widest flammability range of any gas with which I'm familiar, making it an interesting gas to work with. ;)
- frandroid 8y agoThe utility generators probably don't worry too much about leaks, since they can just refill with new, abundant hydrogen, too. It would be amusing to have a hydrogen-cooled hard drive for which you'd have to regularly refill the water tank so that it could generate more hydrogen for itself. :)
- deleted 8y ago[deleted]
- tzahola 8y agoYeah, and it would have a little Bunsen burner to safely get rid of waste hydrogen!
- HankB99 8y agoYes, it's the hydrogen that leaks out that's the problem. I was told that the way to find hydrogen leaks in plant piping was to walk the line holding a corn broom over the line. When it bursts into flame you found the leak. In an enclosed space it can form an explosive mix with air if it doesn't ignite before it accumulates.
- fnordprefect 8y agoIsn't there also a potential problem with hydrogen embrittlement (depending on what materials are exposed) that you avoid with helium?
- HankB99 8y agoI don't know, but it seems possible. The only references I recall about hydrogen embrittlement were with steam boilers at high temperature and pressure. I suppose like most engineering solutions it comes down to the various tradeoffs between cost and effectiveness for hydrogen vs. helium.