Localized cooling isn't hard. Laser cutters do it; they have a tiny nozzle spraying compressed air (in some machines, an inert gas) on the cutting site. For te
by Animats 9y ago
Localized cooling isn't hard. Laser cutters do it; they have a tiny nozzle spraying compressed air (in some machines, an inert gas) on the cutting site.
For temperature feedback, a non-contact IR sensor would work. Operate the IR sensor only during the off time of the laser (presumably pulse-width modulated) and you can read the temperature while heating.