3 ms·
It's a shame you got downvoted, because lens caps were really tricky on the Russia landers. https://en.wikipedia.org/wiki/Venera#Venera_camera_successes_and_fa
by DanBC 9y ago
It's a shame you got downvoted, because lens caps were really tricky on the Russia landers.
https://en.wikipedia.org/wiki/Venera#Venera_camera_successes_and_failures https://en.wikipedia.org/wiki/Venera#Venera_camera_successes...
> The Venera 9 and 10 landers had two cameras each. Only one functioned because the lens covers failed to separate from the second camera on each lander. The design was changed for Venera 11 and 12, but this change made the problem worse and all cameras failed on those missions. Venera 13 and 14 were the only landers on which all cameras worked properly; although unfortunately, the titanium lens cap on Venera 14 landed precisely on the area which was targeted by the soil compression probe.
- baybal2 9y agoYes, the issue was stupidly trivial. They put a very tight fitting steel cap on an aluminium camera housing. They attempted to over-engineer the thing further by adding explosive bolts to it. That also ended in failure (explosives failed to explode as they decomposed long before they were fired). Finally, a dumb solution was devised: to make the cap to fit inside the bezel and be made from titanium. That finally solved the issue. As the aluminium bezel expanded, the cap loosened up, falling out under its own weight. But that didn't account for another instrument sampling area being right under the camera, where the cap were to fall.