I think your efficiency numbers are too low. Large electric motors, 90-95% efficient. Battery round trip efficiency, 80-85%. High voltage inverters, likely a
by Gibbon1 9y ago
I think your efficiency numbers are too low.
Large electric motors, 90-95% efficient.
Battery round trip efficiency, 80-85%.
High voltage inverters, likely above 98%.
Roughly seems like regen round trip efficiency would be at least 63.5%.
The weight ratio is (45 tons)/(65tons + 45 tons) = .409
Unfactored are rolling friction loses.
- hwillis 9y ago40 kWh regen per trip on 700 kWh total is very likely to have 98%+ charge/discharge efficiency. If it's doing 20 trips per day and a "day" is 8 hours (I suspect it's actually more), then that's what- a ten minute trip? That would be charging at .34 C. A standard slow charge is between .2-.8 C.
- ChuckMcM 9y ago> The weight ratio is (45 tons)/(65tons + 45 tons) = .409 Sproing! Discussing it here I realize that I kept thinking about it as 'can the energy of bringing 65 tons down equal the energy of 45 tons up' but you are absolutely right that really its 110 tons down, and 45 tons up. That certainly helps.