Yes, a lot of older appliances actually had a little toggle switch to change between these. The problem still exists but many of newer machines have its own in
by unsignedint 9y ago
Yes, a lot of older appliances actually had a little toggle switch to change between these.
The problem still exists but many of newer machines have its own inverters so it's less of the issues...
- lb1lf 9y ago-It is not much of an issue on a micro scale - biggest issue today is probably direct-drive electrical motors, which will run too fast (if 50Hz on a 60Hz grid) or too slow (vice versa). Also, running a 60Hz motor on a 50Hz grid will cause it to run hotter (larger current than nominally on 60Hz; also, less efficient cooling as it turns slower). If the designer designed to a price point rather than to a standard, this may be an issue. On the macro scale, however, you've got a problem if, say, you suddenly lose a power plant in the 50Hz region of your country. You cannot then simply make up for the shortfall by distributing the load between all plants in the country (or, unless you're an island nation like Japan - from your neighbours, too) - only the ones in the 50Hz part of it. This is just a long-winded way of saying that the larger your power grid, the more robust it is when a power plant goes offline. The Japanese are in the unenviable position of having two small national grids rather than one large one - and, for an encore, they're on a bunch of islands and likely unable to import significant power from neighbours, too! Hence any plant downtime is felt much harder than it would any other place. Tough luck.