3 ms·
Ugh, you have no idea how annoying that is. I'd like to set up a little MPI/CUDA cluster for personal/friend use but four GPUs (1060/1070) at full tilt works o
by paulmd 10y ago
Ugh, you have no idea how annoying that is. I'd like to set up a little MPI/CUDA cluster for personal/friend use but four GPUs (1060/1070) at full tilt works out to 500-600W right there, which means a standard circuit only runs two boxes maximum.
As far as I can see it's either colo or run a 220V circuit, which is a bit of a non-starter for a hobby project.
Heck, you can even get uncomfortably close to maxing out a circuit with a single box. SLI 1080 Tis = 540W, plus 250W for an OC'd Intel HEDT processor is 800 watts inside the box, or 1000W at the wall (8.25A of 12A continuous). Hope your wife doesn't start the hairdryer while you're gaming...
- kuschku 10y agoHow are you even using vacuum cleaners? Many vacuum cleaners here are 1800 or 2400W, kettles are 3500W, and hair dryers usually above 1800W, too. This all works because you have between one and three 400V/63A triphase circuits per housing unit, but if your US circuits are this tiny...
- ju-st 10y agoGuess why it's 3500W max? Because Schuko is specced for 16A only (and 10A continuously). Where did you get that 25A number from?
- deleted 10y ago[deleted]
- kuschku 10y agoThe 25A is, in the house of my parents (built '05), what each breaker and line support. As a line might be hardwired to multiple sockets, or to an appliance, or might be connected via a CEE plug instead of Schuko, it might support more than 16A. If you build a large-scale GPU Cluster, you won’t connect them all to a single socket, but each to a separate socket, although they might be on the same line. That’s where the 25A can be useful.