Not in Belgium as far as I know. Here 3-phase is only installed when people use heavy duty equipment. The only people I know with 3-phase are joiners.
by UnbornSoul 10y ago
Not in Belgium as far as I know.
Here 3-phase is only installed when people use heavy duty equipment. The only people I know with 3-phase are joiners.
- Tharkun 10y agoI'm not sure about that. Many old electric cookers required a 3-phase hookup. Newer ones don't seem to, so perhaps it's on its way out.
- the_mitsuhiko 10y agoThat sounds very unlikely. I would love a source for that. How do you hook up a cooker then without combining two phases?
- KaiserPro 10y agowe have 220 volts in europe, we don't need to combine phases to get decent wattage with out having to install bus-bars
- the_mitsuhiko 10y agoI am from Europe and here (Austria) you definitely need to hook it up with two phases and we get 230V at a 16A breaker.
- algesten 10y agoOne phase is the standard in UK and Spain too. You don't get the same amount of Watts outs of a hob wired with one phase, and most hobs seem to be possible to wire either way. I'm trying to google a diagram, but I only find a bunch of forum posts that explain. For Neff stuff (the one we have), the connectors are numbered 1, 2, 3, 4 and 5. 1-2-3 would be separate phases in a 3-phase home and joined together for a single phase. https://www.diynot.com/diy/threads/neff-hob-t1-k40x2-wiring-q.431851/ https://www.diynot.com/diy/threads/neff-hob-t1-k40x2-wiring-...
- the_mitsuhiko 10y agoI know nothing about spain but the UK is the exception to all rules, particularly electricity wise. It evennused to have its own color coding and circuit design.
- rleigh 10y agoAll the places I've lived in (UK) used a 32A 240V radial spur with a dedicated breaker with the appliance hardwired, or a regular wall socket on the kitchen ring main, 13A 240V, with a shared breaker (lower power portable appliance). Never seen 2-phase wiring for domestic use.
- DanBC 10y agoI thought, but I could be wrong, that UK cookers use a radial spur with a dedicated breaker, and that sometimes those breakers also include a standard regular wall socket, but this socket (and the cooker) are still on their own radial spur. The cooker should never be connected to a normal kitchen ring main.
- DanBC 10y agohttp://www.electricalsafetyfirst.org.uk/electrical-professionals/wiring-regulations/new,-rewired-and-similar-installations/ http://www.electricalsafetyfirst.org.uk/electrical-professio... > Q1.18 Appendix 15 of BS 7671: 2008 gives advice on ring final circuits and sharing/spreading the load around the circuit. Item (iii) suggests that cookers, ovens and hobs over 2 kW should be on their own dedicated circuit. Why can’t ovens of less than 3 kW be connected to a ring final circuit via a suitable connection point such as a socket-outlet or fused connection unit? > Appendix 15 is intended to give guidance only. Such connection is not prohibited, provided that no part of the ring final circuit will be overloaded as a result. > Regulation number(s) > 433.1.5 So, not forbidden, but if you have new wiring the electrician is going to give the cooker its own circuit.
- rleigh 10y agoJust checked in my new-ish flat where I have an electric oven only (gas hob). It's a 13A square pin standard wall socket, but does have a dedicated breaker, so it is indeed not on the ring main for the other wall sockets. It has a 32A MCB in the consumer unit (same as on the two main rings). Not sure if it's ring or radial without removing the socket.
- irixusr 10y agoWhy can't you have a one (two w/ 180 deg) phase cooker?
- joelhaasnoot 10y agoMaybe not in existing homes, but new Dutch homes are have 3 phase 25A meters.
- megous 10y agoI'm in EU too. We had recently a blown fuse or something in the entire 5 story building, the result was sort of weird: lights were ok in the entire house, half of the power sockets in the flat were ok, half of the power sockets were without power. That's when I realized that each of these 230V circuits are probably connected to a different phase. (Perhaps so that the load gets distributed evenly)