4 ms·
There are lots of small and medium sized reactor schemes.[1] As of 2014, there were four from the US alone, and 36 worldwide. Nuscale is covered starting at pa
by Animats 10y ago
There are lots of small and medium sized reactor schemes.[1] As of 2014, there were four from the US alone, and 36 worldwide. Nuscale is covered starting at page 80 of that study.
NuScale wants to operate their reactor modules in a water pool, with all the reactors at a site sharing the same pool. If anything goes seriously wrong with one unit, the pool gets contaminated. Then all the units, and the spent fuel pool, are inaccessible, and repair becomes a huge problem.
The only reason NuScale is supposed to be cheaper is optimistic safety assumptions. "The NuScale Emergency Planning Zone (EPZ) is expected to
be as near as the site boundary rather than the current 10 miles required by large traditional plants in the U.S." - IAEA. NuScale's design focuses on emergency core cooling, with their water pool approach. But other things can go wrong. Such as leaks. There's a long history of nuclear reactor leaks.
[1] https://www.iaea.org/NuclearPower/Downloadable/SMR/files/IAEA_SMR_Booklet_2014.pdf https://www.iaea.org/NuclearPower/Downloadable/SMR/files/IAE...
- sandworm101 10y agoInstalling partitions in the pool to isolate each reactor should be a very minor expense. They need not even be self-supporting, just watertight enough to prevent mixing. Builing a larger or more partitioned pool shouldnt even enter into the cost equation imho. Water and concrete are rather cheap given the context.
- nine_k 10y agoDraining one section becomes problematic if walls cannot support the weight of the water.
- Animats 10y agoCompare the Babcock and Wilcox (now BWXT) design in the same document. They have a full large containment building around each reactor. If you have a full, large containment structure, serious reactor troubles at the meltdown level are expensive, like Three Mile Island, but not disasters, like Fukushima. At Fukushima, the containment on the plant was a small vessel around the reactor vessel, like NuScale, and it wasn't able to contain the meltdown. NuScale's design assumes there will never be a meltdown.
- marze 10y agoWhy have a common pool in the first place? To save the cost of individual pools? That can't be much compared to the overall costs. More likely you share a common cooling system between reactors. And maybe containment?
- sandworm101 10y agoI think that nuscale approach means there is no cooling system. The reactors are small enough for the pool to passively cool them if so needed.