Need to correct some stuff. Class 2 (arabic numeral) is for limited power sources, regardless of construction class. Class II (roman numeral) indicates a cons
by BJBBB 10y ago
Need to correct some stuff.
Class 2 (arabic numeral) is for limited power sources, regardless of construction class.
Class II (roman numeral) indicates a construction class where safety cannot be dependent on a ground bond.
Class I (roman numeral) indicates safety is dependent on a reliable ground bound.
Class I equipment, depending on the scoped end-use equipment safety standard, can have up to 25mA of leakage.
Class II equipment, depending on the end-use environment, can be limited to 0.25mA of available touch leakage.
A good reference for Class 2 and 3 equipment is the UL5085-x series (same as CSA No66.x).
For the EU, there are no harmonized standards in the Low Voltage Directive that have an equivalent Class 2/3 construction, although there are several safety standards that address requirements for 'inherently limited' power sources.