3 ms·
> You get most of the same benefit for a lower cost with a Powerwall (if the expectation is temporary outage tolerance). Ehh? A Powerwall costs $3500 alone, WI
by dragontamer 10y ago
> You get most of the same benefit for a lower cost with a Powerwall (if the expectation is temporary outage tolerance).
Ehh? A Powerwall costs $3500 alone, WITHOUT the inverter or transfer switch. A Powerwall supplies 3.3 kW, which isn't enough to run a 3-ton air conditioning unit (30 amps x 240 Volts == 7.2 kW).
If you run 15kW (air conditioner plus a few other stuff), you'll need FIVE Power walls for a minimum price of $17500. (Plus the inverter, plus... etc. etc.)
----------
Or, you can get a 16kW generator AND switch for $3300.
http://www.electricgeneratorsdirect.com/Generac-Guardian-6461-Standby-Generator/p13939.html http://www.electricgeneratorsdirect.com/Generac-Guardian-646...
-------
Powerwall is actually a lot more expensive than standard generators. Something like 5x more expensive.
- Tharkun 10y agoErhm, do you honestly expect to keep your A/C running during a power outage? First world problems indeed.. Insulating your property to keep heat out/in is a hell of a lot cheaper than buying enough backup power to keep your A/C running...
- dragontamer 10y ago> Erhm, do you honestly expect to keep your A/C running during a power outage? First world problems indeed.. Yeah. Lets pay $18,000 for a backup solution instead of $3000 one. The real "first world problems" are the guys who have so much money they can afford to purchase based on ethics, as opposed to practicality. ------- My power-outage plan is btw: walk to the mall / library and use their AC. If I were to get a backup unit for my house, it'd be sized for my AC unit for sure however.
- hibikir 10y agoIt depends on where you live. About 15 years ago, the geniuses of our power company decided that they could save on tree trimming near power lines. a few years later, they were bragging about the savings... and then, in the middle of winter, with about 3 feet of snow on the ground, we had an ice storm that took out power for well over half the city. My house was without power for 4 days, with highs in the 20F. There's enough population density our lives were not in danger, but the house was only habitable because we had a generator. And guess what? 5 months later, the summer comes, the tree trimming still wasn't done, and half the city lost power again due to a summer storm. Out for 6 days in our house. Every day we reached the 90s. Good luck insulating yourself from that heat for almost a week! Having A/C was pretty nice. The power company now inspects and trims around lines every couple of years, just to avoid power outages so wide they can't bring power back at an acceptable timeframe. That said, the situation is rather regional: I'd not care about AC or heating in a power outage if I lived in Northern California. Around here, where we can hit the 100s in the summer and go under zero in the winter, you have to care a bit. My friend in Alaska cares even more. So first world problems? Depends on where you live.
- lorenzhs 10y agoRelying on electricity for heating should be on the list of questionable decisions, though. That changes the parameters of emergency planning significantly. We also had temperatures in the nineties for the last five days here, yet nobody has AC in their home. It's not a big problem with insulation. Of course we also don't have non-redundant overland power lines. Power outages we super rare.
- jakub_h 10y agoProper passive house design in the future should ameliorate temperature issues, both in terms of heating and cooling.
- tcbawo 10y agoFrom what I've heard, houses in certain humid and warm regions (like Florida) quickly succumb to mold without air conditioning. In some cases of abandoned properties, the house quickly becomes a total loss.
- Tharkun 10y agoVentilation != aircon. Believe it or not, people lived in Florida before a/c was a thing... And maybe use some damp proofing while you're at it.
- tsjackson 10y agoYou're assuming that the capacity of the Powerwall is all the power available. With a solar-tied backup system, there is power coming in from the modules as well which is additive to the discharge rate of the Powerwall if wired correctly. So even your massive A/C should be useable for a while during daylight hours if your solar system is large enough. Most people here in humid hurricane country opt to have a 15 amp 120v window unit available instead, and limit themselves to a single comfortable room.
- dragontamer 10y ago> You're assuming that the capacity of the Powerwall is all the power available. With a solar-tied backup system, there is power coming in from the modules as well which is additive to the discharge rate of the Powerwall if wired correctly. That still begs the question: why use Solar + Powerwall when Solar + Gas Generator has higher capacity and is cheaper? > 15 amp 120v window unit 1800 W, which is more than half the capacity of your Powerwall. Not enough electricity left over to run a single-room AC and a dishwasher at night. Got an electric oven or stovetop? 4000W or so? Yeah, Powerwall just ain't gonna cut it. 3.3kW capacity is just way too small for the typical house. The answer to backup is frankly Solar + Generator. Battery backup just doesn't have the specs or the price to be practical yet.
- wang_li 10y ago> why use Solar + Powerwall when Solar + Gas Generator has higher capacity and is cheaper? Because Elon Musk! Senpai notice me!
- brightball 10y agoY'all have thoroughly convinced me to disregard Powerwalls :)
- jakub_h 10y agoOr, solar+battery+generator for uninterruped power while still keeping costs low compared to a large battery?
- pipio21 10y ago"which isn't enough to run a 3-ton air conditioning unit (30 amps x 240 Volts == 7.2 kW)." Wow, it always surprises me how much Americans waste and consider it totally normal(I bet you are American, in the rest of the world it would be difficult to emit that expression with a straight face). Have you considered alternatives? My house in sunny Spain spends less than 1Kwatt in August pumping water in a pipeline in the soil that has a big thermal inertia, and small air conditioning units for the air. You don't need more if you have good insulation.
- ashark 10y ago"Geothermal" (as they call it here) of that sort can be had in the US, but it's very expensive to install unless you have a large yard (otherwise you have to dig even deeper) and it's difficult to impossible to recover the cost of the system at sale if you move before saving enough to justify the cost—which itself may be difficult if you consider the opportunity cost of the money, and especially if you take out a loan to do it. The buried hoses/pipes also have a limited lifespan, and will need to be replaced in a couple decades, again at great expense. In short, we don't do stuff like that in the US (at least, not much) because it's often a good way to lose money. Also, I don't know about Spain, but large parts of the US suffer very high humidity through much of the year. Unless you're on an exposed hilltop with a breeze, it's miserable without good air conditioning. Houses aren't build with cooling-via-open-window in mind anymore, either, having fewer and smaller windows than older houses and being built with no thought to positioning the windows and the house itself such that prevailing winds can blow through it. Many interior materials aren't intended to tolerate even moderate temperature and/or humidity swings anymore, and will deteriorate much more quickly under those conditions. So there aren't many days in a year when it's possible to get by with no heating or cooling and just open your windows, either.
- Gracana 10y agoSpain is pretty darn temperate. Average daily highs don't even rise above the 90s in the hottest months. There are a lot of areas in the US that are far hotter, and if you're thinking about taking advantage of solar energy, chances are you're in one of them.
- 10y ago