4 ms·
Dug this out of the datasheet: " Equals 2 machine cycles - one Fetch and one Execute operation for all instructions except Long Branch and Long Skip, which req
by nickpsecurity 10y ago
Dug this out of the datasheet:
" Equals 2 machine cycles - one Fetch and one Execute operation for all instructions except Long Branch and Long Skip, which require 3 machine cycles - one Fetch and two Execute operations."
Max clock is 3.6MHz. So, better than 8 clock cycles but still dog slow compared to most. 3.6MHz is still very usable in lost of control applications, some logging, and possibly trusted coprocessor if simple function. Speed improvement is a must, though, for the 1802/2.
- JoeAltmaier 10y agoI remember the 8080 used 3 clock-cycles for a T-cycles, and 2 or three T-cycles for an instruction. It really took years to get one-instruction-per-clock-cycle. Pretty much all modern processors can do that now (or even three or four per)
- nickpsecurity 10y agoThanks as I couldnt recall how average CPU was then. I was writing it off as possibly the safety/reliability sacking the performance a bit. Still wondering about the "noise immunity" feature. Thought all digital gates had that property.