I have no direct experience with power supplies radiating, except to note that switching frequencies are up significantly, from 20khz twenty years ago to 500khz
by Gibbon1 10y ago
I have no direct experience with power supplies radiating, except to note that switching frequencies are up significantly, from 20khz twenty years ago to 500khz to 2MHZ today. The AM band is something like 700khz to 1.4MHZ.
Higher switching frequencies and the push for higher efficiency[1] also means very fast switch times, on the order of 20-100ns. High speed signals like that contain very strong harmonics which will leak out.
[1] Old guy mentioned to me what you care about is not the efficiency, but the inefficiency. Because that's directly related to heat. Going tom 90% efficient to 95% efficient, who cares! Except you reduced the amount of heat you need to dissipate by half from 10% to 5%.