5 ms·
Well, far from being definitive, but it looks like a regular pc will cost around $227.52 (350 watt psu, $18.96 per month) in electricity per year to run 24/7.[1
by Alupis 11y ago
Well, far from being definitive, but it looks like a regular pc will cost around $227.52 (350 watt psu, $18.96 per month) in electricity per year to run 24/7.[1]
(calculated using $0.06 per kWh, which is rather low for most people in the US)
So, 5,000 machines running 24/7/365 would cost around $1,137,600 annually (5,000 machines * $227.52 per year) in electricity usage alone.
Of that 24 hours per day, we can assume 8 hours of each day the district expected to pay for them to run, so that leaves ~16 hours the district expected the machines to be asleep or off.
24 - 8 = 16 (about 66% of the 24 hour period)
So, the admin was consuming about $12.51 per machine per month the district did not expect.
This comes out to around $750,600 the sys admin potentially cost the district, for a single year. He ran this scheme for 9 years -- so...
$750,600 per year * 9 years = $6,755,400 in additional electricity costs
Keep in mind this is likely rather low, since most places in the US have a significantly higher per kWh fee than the $0.06 per kWh used in these calculations.
I'm certain that this sum alone was enough cause to terminate the sys admin.
Think about all the things the school district could have spent an extra ~$7MM+ on...
[1] http://www.dslreports.com/faq/2404 http://www.dslreports.com/faq/2404
- redblacktree 11y agoSomething is wrong with your math. $227.52/year is $0.62/day Also, bear in mind that PSUs do not use their full rating unless the hardware they are powering requires it. [0] Your number could easily be double what the machines actually used, if the PSU was somewhat oversized, as they typically are. [0]: https://superuser.com/questions/106792/does-a-power-supply-draw-only-as-much-power-as-it-needs https://superuser.com/questions/106792/does-a-power-supply-d...
- Alupis 11y agoSorry, type-o, math is still correct though. Meant it to say "per month" not "per day".
- digler999 11y ago> 350 watt psu, PSU's arent light bulbs. A "350 watt" psu doens't draw 350 watts. That's the theoretical maximum you can draw from it. Sure, SETI was probably drawing a higher load than idle, vs off, but I highly doubt it was drawing 100%. Even more complicated is the heat. If they lived in a cool climate, at least some of the waste heat that was emitted would have been absorbed by the building, which they are (presumably) paying to heat at least a few months of the year. Edit: also if it was a public school, wouldn't they be off for about 3 months over summer ?
- Alupis 11y ago> PSU's arent light bulbs You are right. I was just going off the source I found, which accounted for some of the aspects you point out, but not all. These numbers simply provide a rough estimate, and detail how the sys admin certainly did cost the school district real (and potentially very substantial) sums of money. > Even more complicated is the heat. You make a good case for the winter months, but the opposite would hold true for the summer months when the heat becomes a real issue and additional air conditioning may be necessary, etc... > Edit: also if it was a public school, wouldn't they be off for about 3 months over summer ? Not necessarily. Usually over the summer months (for a traditional schedule school as opposed to a year-round schedule like many public schools are these days) some of the staff is typically on campus monday-friday doing various administrative tasks, workshops, prepping for the next school session, moving classroom furniture, cleaning, etc... IT staff would be included in this, and therefore we can reasonably assume the sys admin was still running his systems.
- nerd_stuff 11y agoHe lived in Arizona which is hot and a school full of space-heaters (humans) will probably run AC more often than heat. What grandparent commenter showed was the school district's numbers are plausible. I doubt the district entered into a legal battle without first consulting an engineer or two about the electric costs.
- ArkyBeagle 11y agoI wonder if anybody even so much as plugged a typical computer used into a Kill A Watt and compared with/without SETI running.
- holyoly 11y agoI have. I tested 3 models of HP that we had on campus which are kind of aging. Here's my results in Watts: HP 6000 Pro SFF - Core2Duo E8400 @ 3GHz - 100% CPU: 70, Idle: 26, Sleep: 2-3, Off: 0-1, HP 6200 Pro SFF - Core i5 3470 @ 3.2GHz - 100% CPU: 83, Idle: 31, Sleep: 2-3, Off: 0-1, HP 6300 Pro SFF - Core i5 2400 @ 3.1GHz - 100% CPU: 100, Idle: 30, Sleep: 2-3, Off: 0-1, It's been a few months now, and I can't remember what I used to max out the CPU. It wasn't SETI @ Home, but it should give you a pretty good approximation. When it was off, it had Wake on LAN enabled, so it still drew some power. But it would fluctuate between 0 and 1.
- ScottBurson 11y agoJust one data point, but I have a machine I run Folding@Home on most of the time, and that is plugged into a Kill-A-Watt. The difference between idle and full folding power is about 70W, as I recall. Not trivial, but 1/5 of what you've estimated here. 15 years ago, the power difference was probably smaller, maybe quite a bit smaller -- modern CPUs are better optimized for low idle power.
- Alupis 11y agoMost schools don't have "modern" computers (by most definitions of the word "modern" at least).
- rtkwe 11y agoYou're probably running a much more powerful processor than the school's computers were. The report is from 2009 at the earliest based on the cited forum post. There were some very low TDP processors during the 2000-2009 time frame that were very common in education systems. Core 2 Duo was <35W TDP and was pretty popular from what I remember. P3 was in the same neighborhood too. https://en.wikipedia.org/wiki/List_of_CPU_power_dissipation_figures#Pentium_4 https://en.wikipedia.org/wiki/List_of_CPU_power_dissipation_...
- vectorjohn 11y agoYou were looking at laptop Core 2 Duo. Desktop was 65 to 105.
- rtkwe 11y agoAh my mistake.
- nadams 11y ago> Think about all the things the school district could have spent an extra ~$7MM+ on... That's assuming they didn't use computers. Your calculation assumes that the computer uses a full 350+ watts of electricity. If it had a 350 watt PSU and was drawing that full load - it would shutdown (I've had this happen). Even then the CPU doesn't require 350 watts of power [1]. The only device that I know of that will use and designed to use a full load is a bitcoin miner. Taking in consideration that these computers might have been left on already. I would argue that he used MAYBE an extra 50 watts of electricity [2]. So assuming $0.10/kw/hr (which is the cost of where I live) - he wasted a whopping $0.12/day or ~$50/year. You have to take into account if the computers were already on. He didn't waste electricity because someone left their computer on - his "waste" would be electricity use that is above that of an "idle computer". It should also be pointed out that if the computer has Mcafee or some other crappy AV the CPU usage would be 100% anyways due to poor programming of the AV software (I have personally seen this many times and you don't know how many times people complain about their slow computer because the AV is using 100% of the CPU). There is no way he wasted $7m - and even if he did and no one noticed that is part of a larger problem. Besides they only claim he wasted $1.2m - $1.6m [3] - with no evidence of how they came up with that number. That is saying he managed to waste over $100k/year (over 9 years) in equipment purchases, electricity etc - and NO ONE noticed this? I find it hard to believe that the people managing the budget were like "$100k unaccounted for this year? no big deal...". And even if it was accounted for and signed off - there should be 2 people fired - his and the guy who approved the purchase. Even from the article: > would find that in a middle of a lesson, the SMART Board had turned off. This has happened to me personally on my own laptop. Not because I was mining bitcoins or running seti@home. In fact I've seen them installed and they are such POS that no instructor I know actually uses it as a SMART board. [1] https://en.wikipedia.org/wiki/List_of_CPU_power_dissipation_figures#Intel_Core_i5 https://en.wikipedia.org/wiki/List_of_CPU_power_dissipation_... [2] http://i.stack.imgur.com/4HQPY.png http://i.stack.imgur.com/4HQPY.png [3] http://www.azcentral.com/news/articles/2009/11/30/20091130searchforaliens1202.html http://www.azcentral.com/news/articles/2009/11/30/20091130se...
- Alupis 11y agoEven using your math: ~$50 per year per computer * 5,000 computers = $250,000 in additional power consumption per year He ran this scheme for 9 years: $250,000 per year * 9 years = $2,250,000 total additional electricity costs No matter what way you run the math, he blew millions of the school district's budget.