2 ms·
Similar issue with the "Coefficient of Performance" in heating and cooling[1], which is the ratio of "energy extracted" to "energy consumed". Since you're just
by SilasX 11y ago
Similar issue with the "Coefficient of Performance" in heating and cooling[1], which is the ratio of "energy extracted" to "energy consumed". Since you're just moving energy around, this value can easily be greater than 100% -- no violation of the laws of thermodynamics! 100% is just as arbitrary a value on this scale. .
However, there's still always a relevant maximum that you should measure relative to, and refrigerators have a theoretical maximum. The maximum ("Carnot") efficiency is the ratio of the higher (absolute) temperature to the temperature difference. For room temperature to freezing, that would be ~300/27 = 11.1 = 1100%.